- 注射针测试仪
- 注射器针架固定力测试器
- 穿刺器刺穿力试验仪
- 医用注射针针尖刺穿力测试仪
- 医用注射针管(针)刚性测试仪
- 医用针管(针)韧性测试仪
- 多功能拉力测试仪
- 注射针韧性测试仪
- 注射针刚性测试仪
- 注射针刺穿力测试仪
- 刚性测试仪
- 注射器测试仪
- 缝合针测试仪
- 缝合线测试仪
- 输液器测试仪
- 留置针测试仪
- 针灸针测试仪
- 刀片测试仪
- 输注泵测试仪
- 安瓿测试仪
- 安全注射器测试仪
- 一次性注射器测试仪
- 安全注射针测试仪
- 一次性注射针测试仪
- 扩张器测试仪
- 医用注射器测试仪
- 医用缝合针测试仪
- 医用缝合线测试仪
- 鲁尔锥头综合测试仪
- 注射针管(针)刚性测试仪
- 医用注射针尖刺穿力测试仪
- 注射器滑动性测试仪
- 注射器密合性正压测试仪
- 输液器泄漏正压测试仪
- 医用缝合针韧性弹性测试仪
- 缝合针刺穿力,强度测试仪
- 医用缝合线线径测试仪
- 手术刀片锋利度测试仪
- 断裂力和链接牢固度测试仪
- 医用注射针测试仪
- 鲁尔接头综合测试仪
- 鲁尔接头测试仪
- 鲁尔锥头测试仪
- 6:100鲁尔接头综合测试仪
- 6:100鲁尔锥头综合测试仪
- 医用注射针管韧性测试仪
- 医用缝合针切割力测试仪
- 医用缝合线张力测试仪
- 牢固度测试仪
- 吻合器刀片切割力测试仪
- 注射针模拟皮肤
- 麻醉穿刺针测试仪
- 检测仪
- 注射针检测仪
- 注射器检测仪
- 输液器检测仪
- 采血针测试仪
- 牙科测试仪
- 口腔手术器械检测仪
- 医用剪检测仪
- 医用剪测试仪
- 吸脂针测试仪
- 自毁注射器测试器
- 自毁注射器测试仪
- 安全注射器自毁测试
- 医疗注射器测试仪
- 导管真空残留、泄漏测试仪
- YY0540-C 导丝抗弯曲性能测试仪
- 麻醉和呼吸设备测试仪
- 导丝破裂工装
- 导丝头端柔软性测试仪
- ZBC33001-JQX牙钻切削试验仪
- QD0325-C导尿管强度测试仪
- F0325-C导尿管牢L固度分离力测试仪
- KKO325-C导尿管球囊可靠性测试仪
- 医用微波消融针测试仪
- 听诊器测试仪
注射针针尖刺穿力测试仪
点击次数:4170 发布时间:2021-05-28
1. GeneralPenetration force of medical injection needle testing apparatus CL15811-Tis designed according to GB15811-2000,(eqvISO7864-1993)clause about “disposable hypodermic injection needle”. The apparatus features user friendly, easy operation , practicality and convenience. As seen figure 1.2.Technical parameter Operation temperature:5~40℃ Relative humidity:45~80%Supply voltage :220V±22V/50HZ±5HZMax power :60WLoading range: 0~10.0NAccuracy: ±0. 01N。3.Schematic DiagramPenetration force of medical injection needle testing apparatus CL15811-E consists of MPU, Pressure measurement unit, distance measurement unit, micro printer etc. As seen figure 2.4. Installation and Commissioning:4.1 Put the apparatus on the working table horizontally4.2 Plug the apparatus in4.3 Install the medical needle on the clamping fixture4.4 Adjust the height of loading rack, make the distance between medical needle and clamping fixture be 2~5mm, as well as make the needle align withФ10 hole in the fixture4.5 According to the operation instruction below to set the apparatus and conduct the test. please see the chapter 5th 5 .Operation instruction There are four operation keys on the apparatus: Left Key,Down Key ,Right Key,Enter Key.5.1Welcome screenSwitch on the power, the welcome screen will be displayed, please see the figure 3. Press or to select language, Press to enter the next page5.2Main menu operation:shows the main menu page, you can choose the testing items through main menu page, conduct a test, set time etc. please see Figure 4. 5.2.1 needle tubing classification When the cursor is moved to “needle tubing type”, press or , “Normal wall”, “Thin wall” , “Ultra-thin wall” are displayed in turn. Press , to move the cursor to “Needle tubing size”。5.2.2 Needle tubing size when the cursor is moved to “Needle tubing size”, press or, Needle tubing size are displayed in turn. Press to move the cursor to the next line。5.2.3 TestCountwhen the cursor is moved to “TestCount”, Pressor, 8times, 13times, 20times are displayed in turn5.2.4 Modewhen the cursor is placed over “Report Mode” , the system default is print mode, press to move the cursor to the next line5.2.5 Perform Test when the cursor is moved to “ Perform Test”, Press to move the cursor to the next line. After the testing needing tubing is installed, you can press to enter the test mode, please see the chapter 5.3 for detail operation5.2.6 Move Up when the cursor is moved to “Move Up” Press the apparatus stand will move upward, and the screen will display “Press Enter to stop”, at this point, you can press“Enter”key to stop the move of apparatus stand ,Press the stand can move upward again. Press to move the cursor to the next line 5.2.7 Move Downwhen the cursor is moved to “Move Down” Press the apparatus stand will move downward, and the screen will display “Press Enter to stop”, at this point, you can press“Enter”key to stop the move of apparatus stand ,Press the stand can move downward again. Press to move the cursor to the next line5.2.8 TimeWhen the cursor is moved to “Time”, you can set the system time. Press in a row to move the cursor over the digits of time in turn. Press to change the digit which be selected by cursor. Press to save the time you have set. Pressto move the cursor to the next line5.2.9 System ParameterWhen the cursor is moved to “System Parameter”, Press You can enter the parameter set mode which need a password to enter (you need to contact the vendor to get a password). Press to move the cursor to the next line.5.2.10 Verify When the cursor is moved to “Verify” Press to enter the verifying mode, you can verify if the measured values are accurate by using standard weights, If the numbers displayed on apparatus do not match the standard weights, you need to re-set the parameters. Press to move the cursor back to“needle tubing classification”5.3 Testing operationEnter the testing page, the measurement is carried out automatically, the clamping fixture moves downward, when it contacts the artificial skin, the system begins to draw pressure curve. After the fixture is moved the distance 8mm downward, the system will find the Max value of the curve automatically and the fixture goes back to the original position, as well as the operation menu pops out. Figure 5. shows the testing page If something wrong happens during testing, then press ENTER KEY to end the test.After the tested is completed, “Operation tips” pops out, you find the peak value , print curve, check up reports and re-test. Press to move the cursor, Press to carry out the corresponding operation, please read 5.4 for detailed operation about finding peak value, read 5.5 for detailed operation about checking up report5.4 Operation about finding peak value Figure 6 shows finding peak value modethe pressure curve has more than one peaks, when you choose the mode for finding peak value, short press or move the cursor one space to left or right, Long pressor move the cursor to next peak Press to confirm the current peak value. Press to choose print mode or return to back page.5.5 Check up testing reportChoose the “check up report” shown in figure 7., the screen will enter the testing report pagepressor to select ”Print”, “Re-test”, “Delete”, “Return”, if you select “Print” and press , the test report is printed; If you select “Re-test” and press , the next test will be performed; if you select “Delete” and press , the last test results are deleted; if you select “Return” and press , the screen returns to the main menu.5.6 System parameterIf you want to enter “system parameter” in the MainMenu to set the parameters, you need to contact the vendor to get a password. You can not set the system parameters without the password.6. Additional considerations6.1 Operation crew should be familiar with the manual of this apparatus6.2 The instrument should be calibrated every year.6.3 The vendor carries out the“three guarantees” (for repair, replacement or compensation of faulty products) for this apparatus, The quality assurance period is one year long, during this time, if the damages to the apparatuss are not artificial, the supplier is responsible to the maintainance and replacement.6.4 Non-professional staff should no enter “system parameter”6.5 If the users want to verify if the apparatus runs correctly, you can enter “ verify” of 10th item in the Main menu and use the standard weights to verify. If the apparatus can not run properly, the interior system parameters need to be re-set, at this time, please contact the vendor for help. Contact Tel: 7. packing list7.1 Main unit 1pc7.2 Three-cord power cord 1pc7.3 Operator’s manual 1pc7.4 Product examination report 1pc7.5 Product certificate (attached on the apparatus) 1pc7.6 Set of clamping fixture1pc7.7 Printer instruction1pc7.8 set of standard weights1box7.9 Fuses2pc